Pneumatic Spot Machines Vulcan Pneumatic operated spot welding machines are offered in 20, 30, 50 & 75 KVA models. All machines are made of steel fabricated rigid structures eliminate the minutes spot deflection. Pneumatic Spot welders are designed for high speed production jobs meet vast needs of metal fabrication industries including sheet metal components, cross wire welding, electro brazing, resistance heating etc.
Salient Features
- Transformer: Low leakage (High Linkage) design, proper cooling and insulation including winding varnishing by vacuum pressurized impregnating system to enhance reliability and service life.
- Time & Current Control: Current setting from min. to max. can done by a 6 positon, off load tap switch & micro processor based synhronous controller with 25 different programmers of setting is incorporated with these machines in order to obtain consistent and accurate weld results of the jobs.
- Electrodes: One pair of 2 straight electrodes made from hardened copper-alloy is supplied with the equipment. Other types of spare electrodes can be supplied on specific orders.
- Cooling: Electrodes and arms are provided with water cooling arrangement with hose connections. (Optional for 20 & 30 KVA model).
Technical Specifications
|
Model
|
Unit
|
VPS-20
|
VPS-30
|
VPS-50
|
VPS-75
|
|
KVA Rating @ 50% Duty Cycle
|
KVA
|
20
|
30
|
50
|
75
|
|
Nominal Throat Clearance
|
MM
|
250
|
250
|
250
|
250
|
|
Throat Depth
|
CM
|
50
|
50
|
50-60
|
50-75
|
|
Max. Available Short Circuit Current
|
K Amps.
|
12
|
18
|
23-18
|
26-20
|
|
Max. Electrode Force @ 6 Kg/cm2
|
|
450
|
450
|
480
|
480
|
|
Upper Electrode Stroke Max
|
MM
|
50
|
50
|
50
|
50
|
|
Primary Supply Voltage
|
Volts
|
415
|
415
|
415
|
415
|
|
(2 Lines of 3 Phase Supply)
|
Insulation Class
|
A
|
|
Machine Dimension L
W
H
|
MM
MM
MM
|
1100
500
1640
|
1100
500
1640
|
1350
600
1750
|
1350
650
1750
|
|
Approx Weight with Arm
|
Kgs
|
220
|
250
|
295
|
360
|
|
Customer to Provide the Following Services
|
|
External Water Supply at max. Temp. 30o C
|
Lit./Min.
|
7
|
7
|
10
|
10
|
|
Size of mains supply Copper Cabal
|
MM2
|
16
|
25
|
35
|
50
|
|
Main Supply switch fuse Rating 500 Volts
|
Amps
|
35
|
75
|
100
|
150
|
|
Delayed Action fuse Rating Amps.
|
Amps
|
30
|
60
|
90
|
140
|
Note: Due to policy of continuous improvement, we reserve the right to modify the equipment and change specifications without prior notice.
|